Category:

SL 194

True Double Beam Atomic Absorption Spectrophotometer

High Performance Flame Atomic Absorbance Spectrophotometer (AAS) with Flexibility, Simplicity, Works in Standalone mode without computer, Fully Automated Gas Control System & Safety Features.
Description
ELICO's SL- 194, Atomic Absorption Spectrophotometer is fully automated and delivers a new level of flexibility and simplicity. It can work as standalone mode for routine analysis and can also be fully PC Controlled. The selected element lamp is automatically aligned in the built-in 8 lamp turret which automatically recognizes coded HCL lamps and loads their operating parameters.
Applicable Industries
Features
Burner Alignment
Double Beam
LCD
Auto Ignition
PC
  • Built in 4 Line LCD Graphical Display
  • Automated (6/8)  lamp turret compatible to coded & non-coded HCL Lamps with independent Power Supply for warm-up
  • High Energy True Double Beam Optics with Narrow Beam, fully sealed and Quartz over coated mirrors
  • Background correction with D2 lamp source
  • Integral Auto gas control system with LCD display
  • Automatic Ignition and Flame Control with Full Saftey Interlocks
  • Automatic Lamp Alignment
  • Burner Movement in all three directions – height, rotation and lateral.
  • Modes of operation include Absorbance, Emission, Concentration and Standard Addition
  • Optional : 21 CFR Part 11 PC Software, Auto Sampler, Hydride and Cold Vapour Generator.
Specifications
SPECTRAL
Range 185 to 900 nm
Bandwidth Automatic variable slit from 0 to 2.5 nm continuously variable with increment of 0.1 nm
Readability 0.1 nm
Accuracy ± 0.5 nm
Repeatability ± 0.2 nm
PHOTOMETRIC
Range0 to 2 Abs
Accuracy± 0.010 Abs at 1.0 Abs
Integration Time0.04 to 99 sec
LIGHT SOURCE
6/8 Lamps Automatic Turret with Independent Power Supply compatible to coded and non coded HC Lamps.
MONOCHROMATOR
Czerney Turner 1/3 m with 1800 lines/mm Holographic Grating and Hard Coded Optics.
BACKGROUND CORRECTION
Deuterium Lamp (D2)
BURNER
Titanium construction, Premix Laminar Flow100mm burner for Air – Acetylene (C2H2)
Optional – 50 mm burner for Nitrous Oxide (N2O) –  Acetylene (C2H2)
The Spray Chamber is made of Inert Material .i.e., PTFE (Teflon) fitted with adjustable impact bead Aerosol
NEUBULIZER
Made of fully Inert Material with 90% Platinum and 10% Iridium Alloy Capillary
SAMPLE FEED RATE3 to 8 ml/min (Adjustable)
DETECTOR
Wide Range Photo Multiplier Tube (PMT)
FLOW CONTROL
Integral Auto Gas Control System with LCD Display, Keyboard and all Fault Indicators with all safety features
Automatic Flame Changeover, Auto Ignition and Shut Off
Optimization of Flame Conditions for each Element with programmable Flame Control
SAFETY FEATURES
Full Safety Interlocks including Pressure Sensors on both lines, Flame failure Detection, Burner Presence and Recognition, Nebulizer Presence and Drain Sensor, Power Failure Protection and Emergency Flame Shut Off Switch and Flash Back Arrester on the Cylinder
SYSTEM UPGRADATION
Instrument can be upgraded to Auto Sampler, Hydride and Cold vapour Generator
ACCESSORIES SUPPLIED
With Instrument100 mm burner for Air – C2H2 , Nebulizer with SS Capillary, Back Ground Correction with D2 Lamp, Oil free Air Compressor with 100% Dustfree Air Filter, Acetylene (C2H2) regulator with Flashback Arrester.
At extra Cost50 mm burner for N2O – C2H2 , Nebulizer with Pt – Ir Capillary, N2O Regulator, Nitrogen Regulator, HC Lamps for desired Elements coded or non coded, Hydride and Cold vapour Generator, Printer, Computer, PC Software, Exhaust Fumehood Chamber, Servo Controlled Voltage Stabilizer of suitable rating, Acetylene Gas Cylinder, Nitrous Oxide Gas Cylinder and Nitrogen Gas Cylinder.

Reviews

There are no reviews yet.

Be the first to review “SL 194”

Your email address will not be published. Required fields are marked *

Start typing and press Enter to search

Shopping Cart

No products in the cart.