CL 52D
Turbidity Analyzer with 5" color graphical display
A new level of flexibility and simplicity
DESCRIPTION
CL-52D, Turbidity Analyzer providing accuracy and reliability. With a resolution of 0.01 nephelometric turbidity units at low turbidity readings and an extended range to 1000 NTU.
APPLICABLE INDUSTRIES
FEATURES
Double Beam
LCD Display
Auto Ignition
PC
- Microprocesor and Microcontroller based user friendly, Menu driven with printer interface and optional PC attachment through RS232C Interface
- Narrow Beam Optics, fully sealed and Quartz over coated mirrors
- 2 Lamp Holder with independent power supplies for warm-up
- Background correction with D2 lamp source
- Integral gas control system with panel flow meters
- Precise Knobs for Vertical, Horizontal and Rotational alignment of Titanium Burner
- Modes of operation include Absorbance, Emission, Concentration and Standard Addition
- Optional : 21 CFR Part 11 PC Software Hydride and Cold Vapour Generator
SPECIFICATIONS
SPECTRAL | |
Range | 185 to 900 nm |
Bandwidth | Automatic variable slit from 0.15 to 3.0 nm continuously variable with increment of 0.15 nm |
Readability | 0.1 nm |
Accuracy | ± 0.5 nm |
Repeatability | ± 0.2 nm |
CLICK TO SEE MORE
PHOTOMETRIC | |
Range | 0 to 2 Abs |
Accuracy | ± 0.010 Abs at 1.0 Abs |
Integration Time | 0.04 to 99 sec |
LIGHT SOURCE |
Hollow Cathode Lamps (HCL) |
MONOCHROMATOR |
Czerney Turner 300 mm with 1200 lines/mm Holographic Grating of High Density Hard Coded Optics. |
DETECTOR |
Wide Range Photo Multiplier Tube (PMT) |
FLOW CONTROL |
Integral Gas Control System with Panel Flow Meters |
BURNER |
Titanium construction, Premix Laminar Flow100mm burner for Air – Acetylene (C2H2) |
Optional – 50 mm burner for Nitrous Oxide (N2 O) – Acetylene (C2H2) |
The Spray Chamber is made of Inert Material .i.e., PTFE (Teflon) fitted with adjustable impact bead Aerosol |
SYSTEM UPGRADATION |
Instrument can be upgraded to Hydride and Cold vapour Generator |
ACCESSORIES SUPPLIED | |
With Instrument | 100 mm burner for Air – C2H2 , Nebulizer with SS Capillary, Back Ground Correction with D2Lamp, Oil free Air Compressor with 100% Dustfree Air Filter, Acetylene (C2H2) regulator with Flashback Arrester. |
At extra Cost | 50 mm burner for N2O – C2H2 , Nebulizer with Pt – Ir Capillary, N O Regulator, Nitrogen Regulator, HC Lamps for desired Elements, Hydride and Cold vapour Generator, Printer, Computer, PC Software, Exhaust Fumehood Chamber, Servo Controlled voltage Stabilizer of suitable rating, Acetylene Gas Cylinder, Nitrous Oxide Gas Cylinder and Nitrogen Gas Cylinder. |