Aquasense
STP
Multiparameter Analyzer for Sewage Treatment Plants
Simple and exact water analysis – a compact measurement & monitoring system
Description
AquaSense STP - Multi parameter Analyzer is a robust instrument that monitors water quality at Sewage Treatment Plants (STP). Designed for all-weather conditions and environments, the analyzer measures Flow, pH, COD, BOD and TSS in water samples.
While data is stored locally, it can be automatically uploaded to a cloud server and the analytics can be monitored through a web-based configurable dashboard.
Applicable Industries
Water
Features
Designed for dusty and humid indoor/ outdoor/ industrial conditions
Ultrasonic non-contact & Capacitive level techniques for Flow Measurement
Reliable Measurements without reagents
Innovative Long-life UV-Led Technology
Automatic air jet cleaning for all sensors
Integrated GPS & 4G Modules

(Optional)
Parameters
Flow
pH
COD
BOD
TSS
- Reliable, Low maintenance design
- Integrated GPS & 3G/4G Modules for Location Tracking and Uploading data to Cloud Server
- Supports you to monitor flow, pH, COD, BOD & TSS in real time from all your site stations from single centralized platform
- Real-time alerts over SMS
- Programmable Measuring Frequency
- Customized Online Reports
- Real time & Historical data, trends
- Dashboards, reports, and export functionality
Flow
- Open channel & pipe flow measurement
- Ultrasonic non-contact & Capacitive level techniques
- Designed for dusty and humid indoor/ outdoor/ industrial conditions
- Easy mounting
COD/ BOD/ TSS
- Reliable measurement without reagents
- Innovative long lifetime UV-LED technology
- Automatic air jet cleaning for all sensors
Specifications
| pH Analyser | |
| Measurement Range | 2 to 14 pH |
| Resolution | 0.01 pH |
| Accuracy | ≤ 0.1 pH (±1 digit) |
| Electrode Calibration | 1 to 5 points calibration |
CLICK TO SEE MORE
| Temperature | |
| Measurement Range | 0 to 100°C |
| Resolution | 0.1 °C |
| Accuracy | ±0.3 °C |
| General | |
| Power supply | 230V AC, 50Hz |
| Interface. — Digital | RS232, RS485(Modbus RTU),Ethernet (TCP/IP) |
| — Analog | 4 to 20mA |
| User Alarms | Two programmable alarms (5A @ 240V) |
| Enclosure | IP65 rated for outdoor installation |
| Cellular Network | Dual band GSM/GPRS/EDGE 900/1800 MHz, Multi band L TE-TDD, LTE-FDD, WCDMA SIM card Interface |
| COD/BOD/TSS | |
| Measurement principle | Reagent-free UV-VIS absorption measurement. 2 LED (254nm, 530nm) with Photo Diode |
| Optical path | 1mm/10 mm |
| Turbidity compensation | At 530 nm |
| Response time | 4 sec |
| Measurement Range | COD: 0 – 1500 mg/L BOD: 0 – 500 mg/L TSS: 0 to 1000mg/L |
| Accuracy | 0.20% |
| Resolution | — |
| Sample temperature | +2 to +40 °C |
| Ambient temperature | +2 to +40 °C |
| Storage temperature | +2 to +80 °C |
| Inflow velocity | 0.1 to 10 m/s |
| Repeatability | —- |
| Cycle time | — |







Reviews
There are no reviews yet.