Category:

Flame Atomic Absorption Spectrophotometer (AAS), Rugged, Reliable, Low Cost

Description
ELICO's SL 168, Atomic Absorption Spectrophotometer comes with manual gas control system. It can work as standalone mode for routine analysis and can also be PC Controlled.
Applicable Industries
Features
Burner Alignment
Single Beam
LCD
PC
  • Microprocesor and Microcontroller based user friendly, Menu driven with printer interface and optional PC attachment through RS232C Interface
  • Narrow Beam Optics, fully sealed and Quartz over coated mirrors
  • 2 Lamp Holder with independent power supplies for warm-up
  • Integral gas control system with panel flow meters
  • Precise Knobs for Vertical, Horizontal and Rotational alignment of Titanium Burner
  • Modes of operation include Absorbance, Emission, Concentration and Standard Addition
  • Optional : 21 CFR Part 11 PC Software Hydride and Cold Vapour Generator
Specifications
SPECTRAL
Range 185 to 900 nm
Bandwidth Automatic variable slit  from 0.15 to 3.0 nm continuously variable with increment of 0.15 nm
Readability 0.1 nm
Accuracy ± 0.5 nm
Repeatability ± 0.2 nm
PHOTOMETRIC 
Range0 to 2 Abs
Accuracy± 0.010 Abs at 1.0 Abs
Integration Time0.04 to 99 sec
LIGHT SOURCE
Hollow Cathode Lamps (HCL)
MONOCHROMATOR
Czerney Turner 300 mm with 1200 lines/mm Holographic Grating of High Density Hard Coded Optics.
DETECTOR
Wide Range Photo Multiplier Tube (PMT)
FLOW CONTROL
Integral Gas Control System with Panel Flow Meters
BURNER
Titanium construction, Premix Laminar Flow100mm burner for Air – Acetylene (C2H2)
Optional – 50 mm burner for Nitrous Oxide (N2 O) –  Acetylene (C2H2)
The Spray Chamber is made of Inert Material .i.e., PTFE (Teflon) fitted with adjustable impact bead Aerosol
SYSTEM UPGRADATION
Instrument can be upgraded to Hydride and Cold vapour Generator
ACCESSORIES SUPPLIED 
With Instrument100 mm burner for Air – C2H2 , Nebulizer with SS Capillary,  Oil free Air Compressor with 100% Dustfree Air Filter, Acetylene (C2H2) regulator with Flashback Arrester.
At extra Cost50 mm burner for N2O – C2H2 , Nebulizer with Pt – Ir Capillary, N2O Regulator, Nitrogen Regulator, HC Lamps for desired Elements, Hydride and Cold vapour Generator, Printer, Computer, PC Software, Exhaust Fumehood Chamber, Servo Controlled voltage Stabilizer of suitable rating, Acetylene Gas Cylinder, Nitrous Oxide Gas Cylinder and Nitrogen Gas Cylinder.

Reviews

There are no reviews yet.

Be the first to review “SL 168”